IS300 Series Servo Drive User Manual Appendix
- 71 -
Function
Code
Name Setting Range Min. Unit Default Property
U1-00 Real-time angle 0.0°–359.9° - - ●
U1-01
Reference oil
pressure
0.0 kg–system oil pressure
(A3-02)
- - ●
U1-02
Feedback oil
pressure
0.0 kg–max. oil pressure
(A3-03)
- - ●
U1-03
Motor rotational
sped
-9999–30000rpm - - ●
U1-04 AI1 voltage -10.00–10.000 V - - ●
U1-05 AI2 voltage -10.00–10.000 V - - ●
U1-06 AI3 voltage -10.00–10.000 V - - ●
U1-07 AI1 null shift -10.00–10.000 V - - ●
U1-08 AI2 null shift -10.00–10.000 V - - ●
U1-09 AI3 null shift -10.00–10.000 V - - ●
U1-10 Reference ow
0.00 Hz–max. frequency
(F0-10)
- - ●
U1-11
Resolver signal
interference
degree
0–1000 - - ●
U1-12 Reserved - - - ●
U1-13
CAN COM
interference status
0–128 - - ●
U1-14
Number of CAN
sendings
0–65535 - - ●
U1-15
Number of CAN
receivings
0–65535 - - ●
Group A0: Weak Magnetism and SVC Control Group
A0-00
Weak magnetism
control mode
0: Direct calculation
1: Automatic adjustment
1 0 ★
A0-01
Weak magnetism
current coefficient
80%–200% 1 100% ★
A0-02
Weak magnetism
current upper limit
0–120 1 100 ★
A0-03
Weak magnetism
Integral multiples
200–1000 1 400 ★
A0-04
Weak magnetism
coefficient
0–100 1 4 ★
A0-05
Output phase
loss PWM
detection time
0–63000 1 0 ★
Group A1: PG Card Parameters