Appendix IS300 Series Servo Drive User Manual
- 72 -
Function
Code
Name Setting Range Min. Unit Default Property
A1-00 to
A1-01
Reserved - - -
A1-02
Encoder
installation angle
0.0°–359.9° 0.1° 0.0°
A1-03
Select the reverse
direction of
feedback
speed
0–1 1 0
A1-04
Number of pair
poles of resolver
1–50 1 1
A1-05
Resolver signal
fault detection time
0.000: Detection invalid
0.001s-60.000s
0.001s 0.000
Group A2: CAN COM parameters
A2-00
Baud rate
selection
0: 20k
1: 50k
2: 125k
3: 250k
4: 500k
5: 1M
1 5
A2-01 CAN COM address 1-255 1 1
A2-02
CAN COM
continuous time
0.0S: Invalid
0.1–-600.0s
0.1s 0.3s
A2-03
CAN multi-pump
mode
0: Broadcast mode
1: Multi-master mode
1 0
A2-04
CAN slave
address 1
0–65535 1 0
A2-05
CAN slave
address 2
0–65535 1 0
A2-06
CAN slave
address 3
0–65535 1 0
A2-07
CAN slave
address 4
0–65535 1 0
Group A3: Pump Control Parameters
A3-00
Oil pressure
control mode
0: Non-oil pressure control
mode
1: Driver oil pressure
control mode 1 (via CAN
COM)
2: Driver oil pressure
control mode 2 (via AI)
3:CAN oil pressure mode
(For special use)
4: Reserved
0 0