Appendix IS300 Series Servo Drive User Manual
- 80 -
Function
Code
Name Setting Range Min. Unit Default Property
F4-04
DI5 function
selection
18: Frequency source
switchover
19: UP and DOWN setting
clear (terminal, operation
panel)
20: RUN command
switching terminal
21: Acceleration/
Deceleration prohibited
22-31: Reserved
32: DC braking command
33: External fault normally
closed input
34: Frequency setting
enabled
If it is not set, it is valid by
default. When modifying
frequency, it controls the
modication effective
moment.
35: Reserved
36: External STOP
terminal
In operation panel control,
it is used to stop the drive,
equivalent to the STOP
key on the operation panel.
37: Control command
switchover terminal 2
It is used to perform
switchover between
terminal control and COM
control.
38: Reserved
39: Switchover between
main frequency source X
and preset frequency
40: Switchover between
auxiliary frequency source
Y and preset frequency;
41-47: Reserved
48: Servo pump PID
selection terminal 1
49: Servo pump PID
selection terminal 2
50: CAN COM enabled
1 0
F4-05 to
F4-14
Reserved Reserved Reserved
F4-15 DI lter time 1–10 1 4
F4-16
Terminal command
mode
0: Two-line 1
1: Two-line 2
2: Three-line 1
3: Three-line 2
1 0