Appendix IS300 Series Servo Drive User Manual
- 88 -
Function
Code
Name Setting Range Min. Unit Default Property
F9-18 1st fault type
0: No fault
1: Reserved
2: Acceleration over-
current (Err02)
3: Deceleration over-
current (Err03)
4: Constant over-current
(Err04)
5: Acceleration over-
voltage (Err05)
6: Deceleration over-
voltage (Err06)
7: Constant over-voltage
(Err07)
8: Reserved
9: Under-voltage (Err09)
10: Servo drive overloaded
(Err10)
11: Motor overloaded
(Err11)
12: Input phase loss
(Err12)
- - ●
F9-19 2nd fault type
13: Output phase loss
(Err13)
14: Heatsink overheat
(Err14)
15: External fault (Err15)
16: COM fault (Err16)
17: Contactor fault (Err17)
18: Current detection fault
(Err18)
19: Motor tuning fault
(Err19)
20: Encoder/PG card fault
(Err20)
21: Data overow (Err21)
- - ●
F9-20 Latest fault type
22: Reserved
23: Short circuit to ground
(Err23)
24-41: Reserved
42: CAN COM fault (Err42)
43: Encoder fault (Err43)
44: Speed deviation
protection fault (Err44)
45: Motor temp. fault
(Err45)
46: Oil pressure sensor
fault (Err46)
47-48: Multi-pump parallel
run fault (Err47, Err48)
- -
●
Group FA: Reserved