IS300 Series Servo Drive User Manual Appendix
- 87 -
Function
Code
Name Setting Range Min. Unit Default Property
F9-06
Over-current stall
protective current
100%–200% 1% 150%
F9-07
Power dip ride
through
0: Disabled
1: Enabled
1 0
F9-08
Frequency drop
rate at power dip
ride through
0.00 Hz/s–max. frequency/s
0.01 Hz/s 10.00 Hz/s
F9-09
Fault auto reset
times
0-3 1 0
F9-10
Fault relay action
selection during
fault auto reset
0: Not act
1: Act
1 0
F9-11
Fault auto reset
time interval
0.1s–100.0s 0.1s 1.0s
F9-12
Input phase
loss protection
selection
0: Disabled
1: Enabled
1 1
F9-13
Output phase
missing protection
selection
0: Disabled
1: Enabled
1 1
F9-14
Speed protection
deviation
0.50–50.00 Hz 0.01 Hz 10.00 Hz
F9-15
Speed deviation
protection time
0.0s (protection disabled)
0.1s–20.0s
0.1 10.0s
F9-16
Motor temp.
protection
selection
0: Disabled
1: Enabled
1 0
F9-17
Motor temp.
protection mode
0: DI signal input
1: AI input
2-3: Reserved
1 0