7. Description of Parameters MD500 User Manual
- 200 -
Function Code Parameter Name Setting Range Default
A1-07 Function selection for
AI1 used as DI
WR 0
A1-08 Function selection for
AI2 used as DI
WR 0
$ Function selection for
AI3 used as DI
WR 0
A1-10 Active state selection
for AI used as DI
0: High level active
1: Low level active
000
Unit's digit: AI1
Ten's digit: AI2
Hundred's digit: AI3
)XQFWLRQRIWKH$2DQG3XOVH2XWSXW7HUPLQDOV
7KH0'SURYLGHVDQ$2WHUPLQDO$2$QH[WUD$2WHUPLQDO$2LVSURYLGHGE\WKH,2H[WHQVLRQFDUG0',2
Function Code Parameter Name Setting Range Default
F5-00 FM terminal output mode 0: Pulse output (FMP)
1: Digital output (FMR)
0
F5-06 FMP function selection 0 to 16 0
F5-07 AO1 function selection 0 to 16 0
F5-08 AO2 function selection 0 to 16 1
These three function parameters select the function of the pulse output terminal and the two analog output terminals.
7KHSXOVHRXWSXWIUHTXHQF\UDQJHRIWKH)03WHUPLQDOLVN+]WR)0D[)03RXWSXWIUHTXHQF\)PXVWEHVHWLQWKH
range of 0.01 to 100.00 kHz.
The output range of AO1 and AO2 is 0 to 10 V or 0 to 20 mA.
The functions of the three terminals are listed in the following table.
Value Output Function Range
(Corresponding to 0.0% to 100.0% of Pulse or Analog Output Range)
0 Running frequency 0 to max. frequency
1 Frequency reference 0 to max. frequency
2 Output current 0 to 2 times of rated motor current
3 Output torque (absolute value) 0 to 2 times of rated motor torque
4 Output power 0 to 2 times of rated power
5 Output voltage 0 to 1.2 times of rated AC drive voltage
6 Pulse input 0.01 to 100.00 kHz
7 AI1 0 to 10 V
8 AI2 0 to 10 V (or 0 to 20 mA)
AI3 0 to 10 V
10 Length 0 to max. set length
11 Counting value 0 to max. count value
12 Communication reference 0.0% to 100.0%
13 Motor speed 0 to motor speed corresponding to max. output frequency
14 Output current 0.0 to 1000.0 A
15 Output voltage 0.0 to 1000.0 V
16 Output torque of the motor (actual value,
a percentage of the rated motor torque)
-2 times of rated motor torque to 2 times of rated motor torque
17 Output torque of the AC drive
(actual value, a percentage of
the rated AC drive torque )
-