5. Quick Setup MD500 User Manual
- 78 -
CONTINUE Para. Parameter name Default Commissioning
If any digital output is used
Set DO function
F5-01 FM (switch signal) function selection 0
26: Frequency 1 reached
27: Frequency 2 reached
28: Current 1 reached
&XUUHQWUHDFKHG
30: Timing duration reached
31: AI1 input limit exceeded
32: Load lost
33: Reverse running
34: Zero current state
35: Module temperature reached
36:Software current limit exceeded
37: Frequency lower limit reached (having output at stop)
38: Alarm output
0RWRURYHUKHDWZDUQLQJ
40: Current running time reached
41: Fault output (no output at undervoltage)
F5-02 5HOD\IXQFWLRQVHOHFWLRQ7$7%7& 2
Setting range same as FM;
F5-03 5HOD\IXQFWLRQVHOHFWLRQ3$3%3& 0
6HWWLQJUDQJHVDPHDV)0WKHUHOD\3$3%3&LVRQH[WHQVLRQ,2FDUG