MD500 User Manual 5. Quick Setup
CONTINUE Para. Parameter name Default Commissioning
If any analogue output is used
F5-04 DO1 function selection 1
Setting range same as FM
F5-05 Extension card DO2 function selection 4
Setting range same as FM
F5-06 FM (pulse signal) function selection 0
0: Running frequency
1: Set frequency
2: Output current
3: Output torque (absolute value)
4: Output power
5: Output voltage
6: Pulse input
7: AI1
8: AI2
$,
10: Length
11: Count value
12: Communication setting
13: Motor rotational speed
14: Output current
15: Output voltage
16: Output torque (actual value)
Set AO function
F5-07 AO1 function selection 0
Setting range same as F5-06
F5-08 AO2 function selection 1
Setting range same as F5-06; AO2 is on extension card.
6HWDFFHOGHFHOWLPH
F0-17 Acceleration time 1 model dependent
,IVPRRWKDFFHOGHFHOLVUHTXHVWHG
WRVLI)
WRVLI)
WRVLI)
F0-18 Deceleration time 1 model dependent
WRVLI)
WRVLI)
WRVLI)
Set S-curve
F6-07 $FFHOHUDWLRQ'HFHOHUDWLRQPRGH 3
/LQHDUDFFHOHUDWLRQGHFHOHUDWLRQ
6FXUYHDFFHOHUDWLRQGHFHOHUDWLRQ$
F6-08 Time proportion of S-curve at Accel start 30.0
WR)
) Time proportion of S-curve at Accel end 30.0
0.0% to (100.0% - F6-08)
CONTINUE Para. Parameter name Default Commissioning