EasyManua.ls Logo

Inovance MD520 Series - 5.3 Heat Dissipation Design

Inovance MD520 Series
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mechanical Installation (T10 to T12 Models)
‑103‑
Keep combustible and explosive materials away from the AC drive.
5.3 Heat Dissipation Design
When installing T10 to T12 models in a cabinet, reserve sufficient space for heat
dissipation. A passive‑ventilated cabinet has no fan on the top.
Figure 5‑1 Passive‑ventilated cabinet
Table 5–1 Parameters of a passive‑ventilated cabinet
Model Quantity of Fans Total Air Volume
(CFM)
Effective Area of
the Cabinet Air
Inlet (mm
2
)
Effective Area of
the Cabinet
Outlet (mm
2
)
T9 (132 kW)
2 541 31809 50894
T9 (160 kW)
2 620 31809 50894
T10 (200 kW)
2 586 31809 50894
T10 (220 kW)
2 722 31809 50894
T11 (250 kW)
3 789 47713 76341