EasyManua.ls Logo

Inovance MD520 Series - Page 23

Inovance MD520 Series
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Preparations for Installation
22
Figure 1‑5 Installing multiple AC drives (T1 to T9 models) side by side
Table 1–3 Installation clearance
Power Rating
Clearance (mm)
0.4 kW to 15 kW A 10
18.5 kW to 22 kW A 10
30 kW to 37 kW A 50
45 kW to 160 kW A 50
Dual‑row installation
If one drive needs to be installed above another one, install an air guide plate, as
shown in "
Figure 1–6 Dual‑row installation
"
on page 23
. This can prevent the drive
in the lower row from heating that in the upper row, causing overheat or overload
faults.