EasyManua.ls Logo

Inovance MD520 Series - Configuration with Allen-Bradley and Inovance Masters

Inovance MD520 Series
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EtherNet/IP Communication
‑241‑
Parameter Parameter Name
Unit
Decimal Address
U0‑87
Maximum
forwarding errors of
EtherCAT port per
unit time
1 28759
U0‑88
Maximum error
count of EtherCAT
data frame
processing unit per
unit time
1 28760
U0‑89
Maximum link loss of
the EtherCAT port
per unit time
1 28761
9.7 Communication Configurations
9.7.1 Using an MD500-EN1 Expansion Card on an Allen-Bradley L16ER
Master
In this example, Studio5000 version 32.00.00 is used, the master is 1769‑L16ER‑BB1B,
and the IP address and other information have been configured in advance according
to the guide. Both network ports on the expansion card are available. To use the
expansion card, set F0‑02 to 2, F0‑03 to 9, FD‑00 to 9, and FD‑01 to 3 on the AC drive.