- 9 -
Introduction
Function Description Remarks
Base oor verication
After detecting a position abnormality, the system runs the
elevator to each oor until reaching the terminal oor for
verication, guaranteeing system security.
Passenger unloading
rst upon fault
The system automatically determines the fault level. If the
safety running conditions are met, the elevator rst runs to the
leveling position to unload passengers.
Interference degree
judgment
The system judges the degree of communication interference. Viewed in FA-24
Earthquake protection
When the earthquake detection device acts and inputs a signal
to the system, the elevator lands at the nearest oor and stops
running. After the earthquake signal becomes inactive and the
fault is reset manually, the elevator restores to normal running.
-
Current cancellation in
ramp mode
For the PMSM, after the elevator decelerates to stop, the
holding current of the motor is cancelled in ramp mode,
preventing abnormal noise during current cancellation.
F2-17
Independent working
power supply
The NICE3000new system supports not only three-phase
380 VAC but also single-phase 220 VAC to meet different
applications of the power supply system (such as 220 V UPS)
-
Automatic voltage
identication
The system detects the bus voltage and automatically adjusts
the running speed of the elevator to adapt to the situation of
insufcient power from power supply (such as emergency
UPS).
-
Parallel/Group Control and Other Functions
Parallel control
The system supports parallel control of two elevators and
provides multiple scheduling algorithms to meet requirements
of different customers.
-
Dispersed waiting
In parallel/group control, the elevators can wait at different
oors.
Set in F6-09
Parallel/Group control
exit
If the parallel/group control exit switch of a certain elevator in a
parallel/group control system is valid or the time for exiting the
parallel/group control is reached, the elevator exits parallel/
group control and runs independently. This does not affect
normal running of the parallel/group control system.
-
Parallel/Group control
automatic exit
If an elevator in the parallel/group control system cannot
respond to calls in time due to faults, the elevator automatically
exits the parallel/group control system and runs independently.
This does not affect normal running of the parallel/group
control system.
-
Anti-nuisance function
The system automatically judges the number of passengers
in the car and compares it with the number of registered car
calls. If there are excessive car calls, the system determines
that it is nuisance and cancels all car calls. In this case,
passengers need to register correct car calls again.
F8-08 (Anti-nuisance
function)
Prompt of non-door
zone stop
The system gives a prompt when the elevator stops at a non-
door zone area due to faults.
-
Full-load indication
When the elevator is full-loaded, a full-load indication is
displayed on the HCBs and the elevator directly runs to the
desired oors.
-
Energy-saving Functions
Car energy-saving
If there is no running command within the set time, the system
automatically cuts off the power supply to the lamp and fan in
the car.
F9-01 (Time for fan and
lamp to be turned off)

Other manuals for Inovance Monarch NICE-L-C-4037F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance Monarch NICE-L-C-4037F and is the answer not in the manual?

Inovance Monarch NICE-L-C-4037F Specifications

General IconGeneral
BrandInovance
ModelMonarch NICE-L-C-4037F
CategoryController
LanguageEnglish

Related product manuals