2 System Commissioning
2
2.2.2 Commissioning at Inspection Speed
The NICE3000
new
supports two major control modes:
ā Sensorless vector control (SVC): applicable to inspection speed running for commissioning and fault
judgment running during maintenance of the asynchronous motor
ā Feedback vector control (FVC): applicable to normal elevator running, achieving good driving
performance and running efīæciency in the prerequisite of correct motor parameters
Parameters Related to Motor Auto-tuning
Parameter No. Parameter Name Description
F1-25 Motor type
0: Asynchronous motor
1: Synchronous motor
F1-00 Encoder type
0: SIN/COS encoder
1: UVW encoder
2: ABZ encoder
3: Endat absolute encoder
F1-12 Encoder resolution 0 to 10000
F1-01 to F1-05
Motor rated power
Motor rated voltage
Motor rated current
Motor rated frequency
Motor rated speed
These parameters are model dependent, and
you need to manually input them according to
the nameplate.
F0-01 Command source selection
0: Operation panel control
1: Distance control
F0-01 Command source selection
0: Operation panel control
1: Distance control
F1-11 Auto-tuning mode
0: No operation
1: With-load auto-tuning
2: No-load auto-tuning
3: Shaft auto-tuning 1
4: Shaft auto-tuning 2
5: Synchronous motor static auto-tuning