Introduction
Function Description Remarks
Energy-saving running
with standby power
supply
When the normal power supply is interrupted and the
emergency power supply is used, the system reduces
the running speed of the elevator in the prerequisite of
guaranteeing the smooth running curve.
-
Arrival gong disabled
at night
Within the set time period, the arrival gong is disabled. F5-33 Bit4
2. Optional Functions
Function Description Remarks
Door pre-open
During normal stop, when the elevator speed is smaller
than 0.2 m/s and the door zone signal is active, the system
shorts the door lock by means of the shorting door lock circuit
contactor and outputs the door open signal, implementing door
pre-open. This improves the elevator use efciency.
MCTC-SCB required
Micro-leveling
After landing at a oor, the elevator may move upward or
downward due to the load change and the car door is not
aligned with the ground, which is inconvenient for in and out
of passengers and goods. In this case, the system allows the
elevator to run to the leveling position in the door open state at
the leveling speed.
MCTC-SCB required
Power failure
emergency evacuation
For the elevator congured with standby power supply, the
system uses the standby power supply to implement low-
speed self-rescue in the case of power failure.
MCTC-ARD-C required
Onsite commissioning
The system can control and monitor running of elevators by
using the NEMS software.
-
Commissioning by
mobile phone
The mobile phone can be connected to the controller through
the external WiFi module, and you can commission and
monitor the elevator, and upload and download parameters by
using the cell phone.
Special WiFi and mobile
phone commissioning
software required
Community monitoring
The control system can be connected to the terminal in the
monitoring room. By using the NEMS software, you can view
the oor position, running direction, and fault state of the
elevator.
NEMS, accessories,
and MCTC-MIB
required
IC card
Passengers need to use the IC card to go to oors that require
authorization.
IC card required
STO function
When a fault occurs in the safety circuit, the STO card acts
immediately to cut the output current of the controller and stop
the motor output torque.
Special STO card and
MCTC-JCB-A2
Equipment-roomless
monitoring function
With the monitoring board MCTC-MB-A2, users can view the
running status of the elevator and perform commissioning
outside the shaft and burning.
MCTC-MB-A2 required
3. List of Options
If any optional in the following table is required, specify it in your order.
Name Model Function Remark
External braking unit MDBUN
It is provided for the modes of 37 kW and
above.
-

Other manuals for Inovance Monarch NICE-L-C-4037F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance Monarch NICE-L-C-4037F and is the answer not in the manual?

Inovance Monarch NICE-L-C-4037F Specifications

General IconGeneral
BrandInovance
ModelMonarch NICE-L-C-4037F
CategoryController
LanguageEnglish

Related product manuals