Get Next ALL-Link Record
Get Next ALL-Link Record (0x6A)
What it does Returns the next record in the IM’s ALL-Link Database. The data will follow in an ALL-Link Record
Response
39
message.
What you send
2 bytes.
What you’ll get
3 bytes.
LED indication
None.
Related Commands
IM 0x57 ALL-Link Record Response
39
IM 0x69 Get First ALL-Link Record
36
IM 0x6C Get ALL-Link Record for Sender
38
Command Sent from Host to IM
Byte Value Meaning
1 0x02 Start of IM Command
2
0x6A
IM Command Number
Message Returned by IM to Host
Byte Value Meaning
1 0x02 Echoed Start of IM Command
2
0x6A
Echoed IM Command Number
3 <ACK/NAK> 0x06 (ACK) if an ALL-Link Record Response
39
follows
0x15 (NAK) if there are no more records.
Note
Use this to continue scanning the IM’s ALL-Link Database until you receive a NAK. Begin the scan up
with a Get First ALL-Link Record
36
Command.
In the IM Factory Reset State
11
the ALL-Link Database will be cleared, so you will receive a NAK.

Table of Contents

Other manuals for INSTEON Hub

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INSTEON Hub and is the answer not in the manual?

INSTEON Hub Specifications

General IconGeneral
Product NameINSTEON Hub
Model Number2245-222
ConnectivityEthernet
Communication ProtocolINSTEON
Operating Temperature0°C to 40°C (32°F to 104°F)
Operating Humidity85% non-condensing

Related product manuals