Cancel Cleanup (0x74)
What it does
Cancels cleanup from ALL-Link Command
What you send
2 bytes.
What you’ll get
3 bytes.
LED indication
None.
Related Commands
IM 0x61 Send ALL-Link Command
29
Command Sent from Host to IM
Byte Value Meaning
1 0x02 Start of IM Command
2
0x74
IM Command Number
Message Returned by IM to Host
Byte Value Meaning
1 0x02 Echoed Start of IM Command
2
0x74
Echoed IM Command Number
3 <ACK/NAK> 0x06 (ACK) if the IM executed the Command correctly.
0x15 (NAK) if an error occurred.