EasyManua.ls Logo

Intel SE7500CW2 - Page 90

Intel SE7500CW2
138 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error Reporting and Handling SE7500CW2 Server Board Technical Product Specification
78
Revision 1.40
System CMOS has been corrupted or modified incorrectly, perhaps by an application
program that changes data stored in CMOS. The BIOS installed Default Setup Values.
If you do not want these values, enter Setup and enter your own values. If the error
persists, check the system battery or contact your dealer.
*
0260
System timer error
The timer test failed. Requires repair of system board.
*
0270
Real time clock error
Real-Time Clock fails BIOS hardware test. May require board repair.
0271
Check date and time settings
BIOS found date or time out of range and reset the Real-Time Clock. May require
setting legal date (1991-2099).
0280
Previous boot incomplete - Default configuration used
Previous POST did not complete successfully. POST loads default values and offer to
run Setup. If the failure was caused by incorrect values and they are not corrected, the
next boot will likely fail. On systems with control of wait state
s, improper Setup settings
can also terminate POST and cause this error on the next boot. Run Setup and verify
that the wait-state configuration is correct. This error is cleared the next time the
system is booted.
0281
Memory Size found by POST differed from EISA CMOS
Memory size found by POST differed from CMOS.
02B0
Diskette drive A error
Drive A: is present but fails the BIOS POST diskette tests. Check to see that the drive
is defined with the proper diskette type in Setup and that the diskette drive is attached
correctly.
02B2
Incorrect Drive A type - run SETUP
Type of floppy drive A: not correctly identified in Setup.
02D0
System cache error - Cache disabled
RAM cache failed and BIOS disabled the cache. On older boards, check the cache
jumpers. You may have to replace the cache. See your dealer. A disabled cache slows
system performance considerably.
02F0
CPU ID:
CPU socket number for Multi-Processor error.
*
02F4
EISA CMOS not writeable
Cannot write to EISA CMOS.
*
02F5
DMA Test Failed
Cannot write to extend DMA (Direct Memory Access) registers.
*
02F6
Software NMI Failed
Cannot generate software NMI (Non-Maskable Interrupt).
Device Address Conflict
Address conflict for specified device.
Allocation Error for device
Run ISA or EISA Configuration Utility to resolve resource conflict for the specified
device.
CD ROM Drive
CD ROM Drive identified
Entering SETUP ...
Starting Setup program
Fixed Disk n
Fixed disk n (0-3) identified

Table of Contents

Related product manuals