Serial Setting [2]
Serial setting [2] page
No. Item Description
1
Serial Setting Configure Serial port [1] and port [2]
2
Serial Port [2]
Port [2] is to communicate with the PC Control via Ethernet.
Follow the below instruction to configure Serial port [2] and
press Submit button. Go to “Save & Reboot” page and press
Save & Reboot button to validate the changes.
- Operation mode: TCP Server
- Local socket port: 4002
- Baud Rate: 19200 bps
- Data Bit: 8 Bit
- Stop Bit: 1 Bit
- Parity: None
- Flow Control: None
The ACU control settings should be applied as same above.