Page 20 of 35
with the error icon lit if the zero range is set to 1, 2, or 3. If 4-6 is selected, the zero
button will simply not function when an attempt is made to zero the scale outside
the range. When the number for desired zero range number is displayed press the
Mode button. (0=off, 1=1%, 2=2%, and 3=5%, 4=1%, 5=2%, 6=5%)
7. The display shows “GrAd”. Press the mode button. The display shows the current
setting with the number flashing. Press the Lb/Kg or the ZERO button to cycle
through the graduation options. When the desired graduation setting is displayed
press the Mode button. (grad options 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, or
100)
At this point the display will show “SAvE” for about 1 second and advance to show “CAP”.