Chapter 12 — Adjustments
126 EasyCoder PF2i Bar Code Label Printer User’s Guide (Fingerprint Version)
Label Taken Sensor (LTS) Adjustment
The sensitivity of the LTS may need to be adjusted according to
ambient light conditions and reflective characteristics of the back
side of the media. This is done in the Setup Mode
(Print Defs/LTS), see “Setup Mode” on page 67. You can also
check that the LTS works properly.
The LTS setup options are only displayed if an optional label
taken sensor is installed in the printer.
LTS Adjust
Press Enter. A label is fed out. Remove the label and press Enter
again. A menu shows the sensitivity automatically selected by the
firmware and the range, in which the LTS will work. Press Enter
again and you will proceed to the LTS Test menu.
LTS Test
Press Enter. A label is fed out. Remove the label and a new label
should be fed out automatically. Repeat until you are sure the
LTS works properly. Then press Enter to stop and exit.
LTS Value
Press Enter. You can enter a new value in the range indicated in
the LTS Adjust menu. Min/max values are in the range 0 to 10.