System Maintenance Alert Settings
This section describes the system maintenance alert settings, such as
the odometer distance. To view these settings:
• From the printer Main Menu, select Settings > System Settings >
Maintenance Alerts.
• From the printer web page, click the Configure tab > System
Settings > Maintenance Alerts.
Setting Description Default
Odometer (User
Resettable)
Sets the length of media (in meters) that the printer prints before
the Odometer (User Resettable) alert is sent, if this alert is
configured. Unit of measurement is defined in the Unit of Measure
parameter. Range is 0 to 4294967295.
0
Odometer (Printer) Sets the length of media (in meters) that the printer prints before
the Odometer (Printer) alert is sent. Unit of measurement is defined
in the Unit of Measure parameter. Range is 0 to 4294967295.
0
Replace Printhead Sets the length of media (in meters) that the printer prints before
the Replace Printhead alert is sent, if this alert is configured. Unit of
measurement is defined in the Unit of Measure parameter. Range is
0 to 4294967295.
0
Clean Printhead Sets the length of media (in meters) that the printer prints before
the Clean Printhead alert is sent, if this alert is configured. Unit of
measurement is defined in the Unit of Measure parameter. Range is
0 to 4294967295.
0
Faulty Dot Sets the number of faulty dots on the printhead before the Faulty
Dot alert is sent, if this alert is configured. Range is 0 to
4294967295.
0
Ribbon Low
Diameter
Sets the minimum diameter of the ribbon roll before the Ribbon
Low alert is sent, if this alert is configured. Range is 0 to 200 mm.
0