CHV180 series frequency inverter special for elevator Operation
.29.
5.3.3 Operation
In running state, there are twenty one running parameters which can be chosen to
display or not. They are: running frequency, reference frequency, DC bus voltage, output
voltage, output current, rotating speed, output power, output torque, PID setting, PID
feedback, ON-OFF input state, open collector output state, length value, count value,
step number of PLC or multi-step speed, AI1 voltage, AI2 voltage, AI3 voltage/current,
AI4 voltage, HDI1 frequency, HDI2 frequency. Whether or not to display can be
determined by setting the corresponding binary bit of P7.06. Press the /SHIFT to scroll
through the parameters in right order . Press DATA/ENT + QUICK/JOG to scroll through
the parameters in left order.
5.3.4 Fault
In fault state, the inverter will display parameters of STOP state besides parameters of
fault state. Press the /SHIFT to scroll through the parameters in right order . Press
DATA/ENT + QUICK/JOG to to scroll through the parameters in left order.
CHV180 serials inverter provides much information when fault occur. Please refer to
chapter 8 for more detailed information.