CHV180 series frequency inverter special for elevator Detailed function description
.59.
Function
Code
Name Description
Setting
Range
Factory
Setting
limit
corresponding
output
P6.20
HDO upper
limit
0.0%~100.0% P6.18~100.0
100.0%
P6.21
HDO upper
limit
corresponding
output
0.0 ~ 50.0kHz 0.0~50.0 50.0kHz
The corresponding relationship of A02 output is similar to that of AO1. High speed
pulse output is illustrated as below:
Figure 6.13 Relationship between HDO and corresponding setting.
Function
Code
Name Description
Setting
Range
Factory
Setting
P6.22
FDT level
detection
value
0.00~P0.04 0.00~P0.04
50.00Hz
P6.23
FDT lag
detection
value
0.0~100.0 0.0~100.0
5.0%
These parameters are used to set the detection value of the output frequency and the
lag value of the output action releasing.