Goodrive100-PV series solar pumping inverters Function parameters
-27-
Function
code
Name
Detailed illustration of parameters
Default
Modify
P00.13
Running direction
selection
0: Runs at the default direction. The
inverter runs in the forward direction.
FWD/REV indicator is off.
1: Runs at the opposite direction. The
inverter runs in the reverse direction.
FWD/REV indicator is on.
Modify the function code to shift the
rotation direction of the motor. This effect
equals to the shifting the rotation direction
by adjusting either two of the motor lines
(U, V and W). The motor rotation direction
can be changed by QUICK/JOG on the
keypad. Refer to parameter P07.02.
Note:
When the function parameter comes back
to the default value, the motors running
direction will come back to the factory
default state, too.
In pump application scenarios, the
inverter cannot run in the reverse
direction. This function code cannot be
modified.
2: Forbid to run in reverse direction: It can
be used in some special cases if the
reverse running is disabled.
0
P00.15
Motor parameter
autotuning
0: No operation
1: Rotation autotuning
Comprehensive motor parameter
0