Goodrive100-PV series solar pumping inverters Function parameters
-29-
Function
code
Name
Detailed illustration of parameters
Default
Modify
1: Coast to stop. After the stop command
becomes valid, the inverter ceases the
output immediately. And the load coasts to
stop at the mechanical inertia.
P01.18
Operation
protection
0: The terminal running command is
invalid when powering on.
1: The terminal running command is valid
when powering on.
1
P01.21
Restart after
power off
0: Disabled
1: Enabled
1
P02 Group Motor 1 parameters
P02.00
Motor type
0: Asynchronous motor
1: Reserved
0
P02.01
Rated power of
asynchronous
motor
0.1~3000.0kW
Set the parameter of
the asynchronous
motor.
In order to ensure the
controlling
performance, set the
P02.01~P02.05
according to the name
plate of the
asynchronous motor.
GD100-PV series
inverters provide the
function of parameter
autotuning. Correct
Depend
on model
P02.02
Rated frequency
of asynchronous
motor
0.01Hz~P00.03
50.00
Hz
P02.03
Rated rotating
speed of
asynchronous
motor
1~36000rpm
Depend
on model
P02.04
Rated voltage of
asynchronous
motor
0~1200V
Depend
on model