Goodrive100-PV series solar pumping inverters Function parameters
-30-
Function
code
Name
Detailed illustration of parameters
Default
Modify
P02.05
Rated current of
asynchronous
motor
0.8~6000.0A
parameter autotuning
comes from the correct
setting of the motor
name plate.
In order to ensure the
controlling
performance, please
configure the motor
according to the
standard principles, if
the gap between the
motor and the standard
one is huge, the
features of the inverter
will decrease.
Note: Resetting the
rated power (P02.01) of
the motor can initialize
the motor parameters
P02.02~P02.10.
Depend
on model
P02.06
Stator resistor of
asynchronous
motor
0.001~65.535Ω
After the motor
parameter autotuning
finishes, the set values
of P02.06~P02.10 will
be updated
automatically. These
parameters are basic
parameters controlled
Depend
on model
P02.07
Rotor resistor of
asynchronous
motor
0.001~65.535Ω
Depend
on model
P02.08
Leakage
inductance of
asynchronous
0.1~6553.5mH
Depend
on model