Goodrive100-PV series solar pumping inverters Function parameters
-52-
Function
code
Name
Detailed illustration of parameters
Default
Modify
P15.27
Max. voltage
reference during
max. power
tracking
Min. voltage reference during max.
power tracking~P15.31
Valid in MPPT Max. tracking voltage, the
tracked max. voltage
The default value depends on model.
Model
Max.
voltage
reference
Max.
Vmppt
-SS2
400
400
-S2
400
400
-2
400
400
-4
750
750
400.0V
P15.28
Adjustment of
initial reference
voltage
0.0~200.0V
MPPT begins to change from the
reference voltage
Initial reference voltage =PV
voltage-P15.28
5.0V
P15.29
Adjustment of
upper and lower
limit time of Vmppt
0.0~10.0s
When P15.29 is set to 0.0, the automatic
adjustment is invalid.
If it is not 0.0, the upper and lower limits
of Vmppt will be adjusted automatically
at the inveral set by P15.29. The medium
value is the current PV voltage and the
limit is P15.30:
Maximum/Minimum reference
voltage=Current PV voltge±P15.30 and it
will update to P15.26 and P15.27 at the
same time.
1.0s
P15.30
Adjustment of
5.0~100.0V
30.0V