Goodrive100-PV series solar pumping inverters Function parameters
-54-
Function
code
Name
Detailed illustration of parameters
Default
Modify
input through the relay output.
If the value is 0, it is invalid.
For inverters without the boost module,
the switching point voltage is determined
by the external voltage detection circuit.
For inverters with the boost module, the
switching point voltage is 70V.
P15.34
Threshold to
switch to PV input
P15.33~400.0V
If PV voltage is greater than the
threshold, it can switch to PV input
through the relay output after the time set
by P15.24. To prevent frequent
switching, this threshold must be greater
than P15.33.
If the value is 0.0, it is invalid.
The default value depends on model.
100.0V
P15.35
Rated pump flow
The pump flow is
Q
N
if the pump runs
at the rated pump frequency and rated
lift. Unit: cubic meter/hour.
0.0
P15.36
Rated pump lift
The pump lift is
N
H
if the pump runs
at the rated frequency and rated current.
Unit: meter
0.0
P15.37
Voltage setting at
PV undervoltage
point
When the PV voltage is less than the
preset voltage, the system reports the
PV undervoltage (UV) fault.
The default value depends on the model
.
70.0