EasyManua.ls Logo

INVT GD100-0R4G-SS2-PV - P08 Group Enhanced Functions

INVT GD100-0R4G-SS2-PV
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive100-PV series solar pumping inverters Function parameters
-55-
Function
code
Name
Detailed illustration of parameters
Default
Modify
Model
PV UV
point
-SS2
140V
-S2
140V
-2
140V
-4
240V
Any model with
the boost module
70V
Setting range: 0.0~400.0
P15.39
Model
This function code is provided for users
to change models. For example, if the
user wants to use model -4 (default after
factory delivery) as model -2, P15.39
must be set to 2.
0: -SS2 220V; single-phase input;
single-phase output
1: -S2 220V; single-phase input;
three-phase output
2: -2 220V; three-phase input;
three-phase output
3: -4 380V; three-phase input;
three-phase output
Setting range: 0~3
0
P17 Group State viewing
P17.38
Current of the
main winding
It is the current of the main winding when
applying capacitance-removing to control
the single phase motor.
0.00~100.00A
0.0A
P17.39
Current of the
It is the current of the secondary winding
0.0A

Related product manuals