Goodrive100-PV series solar pumping inverters Function parameters
-58-
Function
code
Name
Detailed illustration of parameters
Default
Modify
PI
P19.05~15.0A
P19.06
Bus reference
voltage
This function code is set to the bus
reference voltage at PV input when the
system contains the boost module. By
default, this function code is set to 350V
for models of 220V and 570V for models
of 380V.
Setting range: 300.0V~600.0V
350.0V
P19.07
Boost voltage loop
KP1
If the difference between the bus
reference voltage and actual bus voltage
is greater than 20V, the boost voltage
loop uses this group PI parameter.
Otherwise, the boost voltage loop uses
the first group PI parameter.
Setting range: 0.000~65.535
0.500
P19.08
Boost voltage loop
KI1
If the difference between the bus
reference voltage and actual bus voltage
is greater than 20V, the boost voltage
loop uses the PI parameters of this
group. Otherwise, the boost voltage loop
uses the PI parameters of the first group.
Setting range: 0.000~65.535
0.080
P19.10
Boost software
version
Once being powered, the boost module
sends its version information to the
converter module.
0.00
Note:
The time when the pump inverter operated to the lower limit of PI output frequency after
inverter start-up is determined by the ACC time.