Goodrive100-PV series solar pumping inverters Function parameters
-57-
Function
code
Name
Detailed illustration of parameters
Default
Modify
1: Detection indicates the system does
not contain the boost module.
P18.11
Current pump flow
Unit: cubic meter/hour
0.0
P18.12
Current pump lift
Unit: meter
0.0
P18.13
MSBs in total pump
flow
This function code displays the 16 most
significant bits (MSBs) in the total pump
flow. Unit: cubic meter
0
P18.14
LSBs in total pump
flow
This function code displays the 16 least
significant bits (LSBs) in the total pump
flow. Unit: cubic meter. Total pump flow =
P18.13*65535+ P18.14
0.0
P18.15
Total pump flow
resetting
Setting this value to 1 can reset the total
pump flow. P18.13 and P18.14 will
accumulate the flow after resetting. After
the resetting succeeds, P18.15 is
automatically set to 0.
0
P19 Group Voltage boost (converter module communicates with boost module
through 485)
P19.00
Boost voltage loop
KP
0.000~65.535
0.500
P19.01
Boost voltage loop
KI
0.000~65.535
0.080
P19.02
Boost current loop
KP
0.000~65.535
0.010
P19.03
Boost current loop
KI
0.000~65.535
0.010
P19.04
Upper limit of the
output current of
boost voltage loop
Upper limit output of mppt voltage loop
PI, upper limit of the boost current loop
reference current
12.0A