58 Freddy
Press on the central active area to view the temperature detected at the core
of the product. This value is a read only value and is updated when it is edited
in the previous screens.
Press again on the central active area that shows the temperature set at the
core of the food to go back to the previous screen.
By pressing the
STOP
key for 1 sec. the cycle is stopped and you go back to
the initial hot functions screen.
If the initial cold storage is not present (set time equal to zero) or is nished,
the unit switches to reviving phase. The display shows the temperature read
by the core probe during heating phase.
Press on the central active area to view the time elapsed from the start of the
reviving phase. This value is a read only value and is updated when it is edited
in the previous screens.
By pressing the
STOP
key for 1 sec. the cycle is stopped and you go back to
the initial hot functions screen. The chamber temperature detected by the air
probe is shown at the top right-hand side of the display.
At the end of the cycle, the appliance emits a sound signal that is repeated
again after 3 minutes. At the end of the ready meal cycle, the following
will appear slowly pulsing. This is to indicate that FREDDY has set
automatically to the storage phase (+60 °C) that can last up to 48 h. In this
phase a sound signal is emitted every 12 h indicating the operating status of
the appliance, until reaching the maximum time. The temperature inside the
chamber detected by the air probe is displayed at the top right-hand side .
Press the key to stop the cycle and go back to the initial screen.
After 48 h the appliance nishes the cycle in progress and emits three sound
signals. The display shows the message "maximum time elapsed".
By pressing in the "maximum time elapsed" information window you will
go back to the main screen.
?
0:22:25
+2°C
STOP
?
45°C
+2°C
STOP
?
45°C
+2°C
STOP
?
+2°C
STOP
0:15:28
?
+60°C
+
MAXIMUM
TIME ELAPSED
CLEANING THE CELL