29. How to check the Unattended Auto-Lock Clock
1. In Admin mode press and hold down
SHIFT ( ) + 5
Solid BLUE LED will change to blinking GREEN
and BLUE LEDs
2. Press the KEY ( ) button and the following happens;
a. All LED’s (RED, GREEN & BLUE) become solid for 1 second.
b. Each RED LED blink equates to ten (10) minutes.
c. Every GREEN LED blink equates to one (1) minute.
d. All LED’s (RED, GREEN & BLUE) become solid for 1 second.
e. LEDs return to solid BLUE
The Administrator is able to check and determine the length of time set for the unattended auto-lock clock by simply noting
the LED sequence as described on the table at the bottom of this page.
To check the unattended auto-lock, first enter the “Admin Mode” as described in section 5. Once the drive is in Admin
Mode (solid BLUE LED) proceed with the following steps.
The table below describes the LED behaviour whilst checking the unattended auto-lock, for instance if you have set the drive
to automatically lock after 25 minutes, the RED LED will blink twice (2) and the GREEN LED will blink five (5) times.
Auto-Lock in minutes RED GREEN
5 minutes 0 5 Blinks
15 minutes 1 Blink 5 Blinks
25 minutes 2 Blinks 5 Blinks
40 minutes 4 Blinks 0
Note: When the datAshur PRO
2
is in Admin Mode, the BLUE LED will remain on and solid for 30 seconds only,
during which time the drive can accept instructions via the keypad allowing it to be configured with a host of security
features. If no key event happens within 30 seconds, the datAshur PRO
2
will exit Admin mode automatically - the
solid BLUE LED switches to a solid RED LED which then fades out to the Idle state (all LEDs off).
To immediately exit Admin Mode (solid BLUE LED), press and hold down the SHIFT ( ) button for a second - the
solid BLUE LED switches to a solid RED LED which then fades out to the Idle state. To access the drive contents
(data), the datAshur PRO
2
must first be in the idle state (all LEDs off) before an Admin/User PIN can be entered.
30. Set Read-Only in User Mode
To set the datAshur PRO
2
to Read-Only, first enter the “User Mode” as described in section 14. Once the drive is in User
Mode (solid GREEN LED) proceed with the following steps.
1. In User mode, press and hold down both “7 + 6
buttons. (7=Read + 6=Only)
Solid GREEN LED will change to blinking
GREEN and BLUE LEDs
2. Press KEY ( ) button
GREEN and BLUE LEDs will change to a solid
GREEN LED indicating the drive is configured
as Read-Only

Table of Contents

Other manuals for iStorage datAshur Pro2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the iStorage datAshur Pro2 and is the answer not in the manual?

iStorage datAshur Pro2 Specifications

General IconGeneral
BrandiStorage
ModeldatAshur Pro2
CategoryStorage
LanguageEnglish

Related product manuals