MAGNETIC SWITCH DOES NOT OPERATE THOUGH
STARTER SWITCH IS TURNED TO “START (ST)”
CHECK IF VOLTAGE IS PRESENT AT MAGNETIC
SWITCH TERMINAL “S” WHEN STARTER SWITCH IS
TURNED TO “START (ST)”
YES
NO
CHECK GROUND CABLE
YES
YES
YES NO
REPAIR
OR
PINION
SLIDING
PART DOES
NOT MOVE
MAGNETIC SWITCH
OR COIL IS
DISCONNECTED OR
BURNED OUT
REPAIR OR REPLACE STARTER
CHECK IF INDICATOR LAMP ON
METER COMES ON NORMALLY
YES NO
DISCONNECTION OR
FAULTY CONNECTION
BETWEEN BATTERY
AND STARTER SWITCH
CHECK CONTINUITY
STARTER SWITCH AND
MAGNETIC SWITCH
TERMINAL “S”
CHECK STARTER
RELAY
FAULTY CONNECTION
OR STARTER SWITCH
REPAIR
CHECK CLUTCH
START
REPLACE STARTER
SWITCH