Advanced Function
CR: constant resistance
mode
CP: constant power mode
End State Set the running state after the
list program is running over.
Normal: After the List
program finishes running,
the working mode and
voltage/ current output
return to the settings
before the List running.
Last: keep outputting the
last step when the dwell
time is over.
Repeat Set the number of list file
repetitions. range: 1 to 65535
Edit Step Edit parameters for each step.
Current/Voltage/
Resistance/Power
Parameter value for Step1
The current appears when CC
mode is selected; the voltage
appears when CV mode is
selected. The resistance
appears when CR mode is
selected; the power appears
when CW mode is selected.
Slope Slope value setting for Step1.
Range: 0.001S-3600S
Time Dwell time setting for Step1.
Range: 0.001S-3600S
Next Select whether to edit the next
step: Yes/No
Insert Step Insert steps before each specified step.
Add Step Add steps after each specified step.
Delete
Step
Delete the selected step.
Delete all Delete all steps.
Copy File
1 to 2
Copy list file1 to file2.
During List editing, the instrument would automatically return to the main
interface if there is no operation for a long period.
Operation Steps:
Copyright © Itech Electronic Co., Ltd.