Operation and Application
b. Rotate the knob to switch On and Off options. After selecting On or Off,
press [Enter] key to confirm.
• Off: After the Trigger key is pressed, the instrument will automatically
run the real-time List file.
• On: After the Trigger key is pressed, the instrument will run the real-
time List file in single step.
c. Press [Esc] to exit the function menu setting.
4. Press the [On/Off] key to turn on the instrument output.
50.0V 3.00A 50.0Hz
List 5 Step 0/ 7 Stop
5. Press the composite keys [Shift] + [On/Off](Trigger) on the front panel to
run the selected List file.
50.0V 3.00A 50.0Hz
List 5 Step 1/ 7 Run
• When List Trigger = On, press the Trigger key once, and the instrument
will run one step of List output.
• When List Trigger = Off, the instrument will output based on defined List.
4.8.3 Dimmer Function
The Dimmer Function aims to adjust the light illuminance intensity by setting the
phase angle and concealing the leading edge or trailing edge waveform. This
IT7200 series power supply supports front and rear phase angle dimmer or
speed adjustment test to verify whether the product has potential quality prob-
lem when the end user uses dimmer or the speed controller.
• Dimmer of leading edge
• Dimmer of trailing edge
Copyright © Itech Electronic Co., Ltd.
46