52
Step 5:
Enter the parameters
Enter the individual parameters and create the desired program (see
Chapter 2.2.2.4 for details).
Step 6:
Load the furnace
Open the furnace head with the [Open furnace head] button and place the object in the furnace.
Whether or which firing tray is to be used is described in Chapter 2.3.1.
Predrying
For locked Ivoclar Vivadent programs, the predrying program can be changed by pressing the [Predrying] button.
For zirconia:
– "Off" for dry machining or "ZrO
2
wet" for wet machining
For the crystallization program:
– "Cryst." for crystallization alone or in conjunction with the glaze spray
– "Glaze" for spray or paste
Predrying must always be activated for crystallization programs.
Step 7:
Start the program
Press the START button. The program is started and the Optical
Status Display lights up in red. The approximate remaining time of
the program is shown on the display.
The indicated remaining time may deviate if particularly high values were entered for the cooling phase.
2. Application