Page #10 background imageLoading...
Page #10 background image
9
2.2.1.1 ALARM SETTING
While setting the alarm, if any detector is triggered (e.g. an open window) the system will react (based on the
system configuration) in one of the following ways:
a Detectors will guard automatically after they switch to standby mode (default setting)
a The system will optically indicate triggered detectors with a segment flashing red for 8 seconds and the
system will set automatically once this period has expired.
a Setting the section with triggered detectors is also possible by pressing the segment button on the right
side repeatedly. This way a user confirms an intention to set the section with a triggered detector (e.g. an
opened window). Otherwise the system will not set.
a A triggered detector will prevent the section from being Set. This status is optically indicated by a fla
shing red segment button. The detector preventing setting will be shown on the keypad’s display menu.
Unsuccessful setting is indicated by yellow a flashing indication button.
Consult the installation with a service technician in order to program the desired behaviour of the system.
2.2.1.2 ALARM UNSETTING
Note: If the “Unset section by authorization only during entrance delay” parameter is enabled, then mere
authorization will unset such section where the entrance delayed has been triggered.
Consult the installation with a service technician in order to program the desired behaviour of the system.
1. Authorize using the keypad.
Sections which can be controlled
are lit up and the backlit indication
button will start flashing green.
2. Press the right button
(the one which isn’t lit up) to set
a particular section. It is possible
to set more sections
subsequently. The delay between
sections selection must not be
longer than 2 seconds.
3. The command is executed and
the keypad acoustically indicates
the exit delay. The section is set
now, only the detectors with a
“Delayed Zone” reaction provide
time to leave the guarded area
during the Exit delay. The segment
button of the set section turns red.
1. When you enter the building
(triggering a detector with a
“Delayed zone” reaction), the
system starts indicating entrance
delay with a continuous tone and
flashing a green segment button
of the section in which the delayed
entrance has been triggered.
Authorize yourself using the
keypad – the green indication light
of the authorization panel starts
flashing.
2. Press the left segment button
of the sections you want to unset.
3. The command is executed
and the segment buttons turn
green to indicate an unset section.
2. OPERATING THE JABLOTRON 100 SYSTEM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jablotron 100 and is the answer not in the manual?

jablotron 100 Specifications

General IconGeneral
Control PanelJA-101K
Events MemoryUp to 1000 events
CertificationsEN 50131 Grade 2
System TypeHybrid wireless/wired security system
CommunicationGSM, LAN
ZonesUp to 120
UsersUp to 50 users
OutputsUp to 32
Backup Battery12V 7Ah (up to 24 hours)
Mobile AppMyJABLOTRON
Number of areasUp to 15
Power Supply230V AC
Wireless RangeUp to 300 meters (open area)
CompatibilityJablotron 100 series components