4
2.1 KEYPAD CODE AUTHORIZATION
Authorization with a user code is done by typing a valid code into a keypad or with an RFID tag.
It is possible to use 4, 6 or 8-digit codes in the system.
The system can be configured to be used with or without prefix codes.
Code with a prefix: nnn*cccc
Meaning:
nnn is the prefix, which is number of the user’s position (0 to 300)
* is a separator (* key)
cccc is a 4, 6, or 8-digit code. Allowed codes… from 0000 to 99999999
Default control panel code Administrator: 1*1234; 1*123456; 1*12345678;
WARNING: The main Administrator code must start with the prefix 1,
The main Service code starts with the prefix 0
Prefix can be disabled for systems with a small number of users. Type of the code can be changed
only by an installation technician.
Code without a prefix: cccc
Meaning:
cccc cccc is a 4, 6 or 8-digit code. Allowed codes… from 0000 to 99999999
Default control panel code Administrator: 1234; 123456; 12345678;
2. OPERATING THE JABLOTRON 100 SYSTEM
CODE
AUTHORIZATION
TYPE DESCRIPTION
Administrator
(Other)
Has access to sections selected by the main Administrator to which the other Administrator can add new
users with the same or lower level of authorization to control sections and PG outputs, assign them with access
codes, RFID tags and cards. Has permission to erase the alarm memory in assigned sections.
When “Administrator-restricted Service/ARC right” is enabled, the administrator code must be authorized
as to confirm access for ARC and Service technicians. The number of Administrator codes (other) is limited
only by remaining capacity of the control panel. There is no code set by the factory defaults.
User This code has access to sections and PG control rights assigned by an Administrator. Users can add/
delete their RFID tags and access cards and change their own telephone numbers. It has permission to erase
the alarm memory in assigned sections. Users can change their codes provided that the system uses Codes with
prefixes. Selected users may have their access to sections limited by a schedule. The number of User codes
is limited only by remaining capacity of the control panel. There is no code set by the factory defaults.
Set This code is allowed only to set a designated section and is allowed to control (ON/OFF) PG outputs which
require authorization. Users with this level of authorization are not allowed to change their code and are not
allowed to erase the alarm memory. The number of Set codes is limited only by remaining capacity
of the control panel. There is no code set by the factory defaults.
PG only Allows the user to control programmable outputs with authorization only. This applies to both switching
on and off. Users with this level of authorization are not allowed to change their code and are not allowed
to erase the alarm memory. The number of PG only codes is limited only by remaining capacity of
the control panel. There is no code set by the factory defaults.
Panic This code is allowed only to trigger Panic alarm. A user of this code is not allowed to change it or erase
the alarm memory. The number of Panic codes is limited only by remaining capacity of the control panel.
There is no code set by the factory defaults.
Guard Code This is a code for a security agency. This level of authorization allows to set the whole system. However the guard
code can unset the system only during alarm or after it expired as long as the alarm memory is still active.
A user of this code is not allowed to change it or erase the alarm memory. The number of Guard codes is limited
only by remaining capacity of the control panel. There is no code set by the factory defaults.
Unblocking code This code is designated to unblock the system after System blocking by alarm. A user of this code
is not allowed to change it or erase the alarm memory. The number of Unblocking codes is limited only
by remaining capacity of the control panel. There is no code set by the factory defaults.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jablotron 100 and is the answer not in the manual?

jablotron 100 Specifications

General IconGeneral
Control PanelJA-101K
Events MemoryUp to 1000 events
CertificationsEN 50131 Grade 2
System TypeHybrid wireless/wired security system
CommunicationGSM, LAN
ZonesUp to 120
UsersUp to 50 users
OutputsUp to 32
Backup Battery12V 7Ah (up to 24 hours)
Mobile AppMyJABLOTRON
Number of areasUp to 15
Power Supply230V AC
Wireless RangeUp to 300 meters (open area)
CompatibilityJablotron 100 series components

Related product manuals