2.2.1.5 TERMINATING A TRIGGERED ALARM
A triggered alarm in progress is indicated by a rapidly flashing red segment button and a backlit
indication button. You need to authorize yourself using the keypad in order to terminate the alarm.
The section remains set, a rapidly flashing red segment button indicates the alarm memory. Indication will keep
on flashing even after the system has been unset.
If the alarm memory indication was activated during your absence, search for the cause of the alarm
in the event history and be very careful when entering and checking the premises or wait until the security agency
arrives (provided your system is connected to an Alarm Receiving Centre).
The segment alarm memory indication remains on until the system is set once again. Alternatively, it can
be cancelled by unsetting the system one more time. Alarm indication can be also cancelled from a keypad with
an LCD display in the Main menu – Cancel warning indication.
Indication of a triggered tamper alarm can be terminated only by a Service technician.
Note: When using the “Default” system profile, it is possible to first select a particular action by pressing
a segment button and then confirm it by authorization using the keypad.
Terminating an alarm using a remote control will also unset the corresponding section.
2.2.1.6 SECTION CONTROL FROM THE KEYPAD’S DISPLAY MENU
Statuses of sections are displayed in the left top part of the display.
A fully set section is shown by a number in a rectangle filled with black colour.
A partially set section is depicted by a framed number.
Control from the keypad menu:
a Authorization by a valid code or an RFID chip
a Enter the menu by pressing ENTER
a Section Control ENTER
a Select the desired section using arrows
a Pressing ENTER repeatedly will change between section statuses
(partially set / set / unset)
a Press ESC to exit the menu
1. Authorize yourself
using the keypad (enter
a code, hold a tag up
to the reader).
2. Press the left segment
button of the section
in which the alarm has
been triggered.
3. Unsetting is finished
and sirens are silenced.
The green flashing
button indicates un-
setting of the particu-
lar section. The red
flashing light indicates
alarm memory.
4. Authorize yourself
and press the green
button again to cancel
the alarm memory
indication.
5. The segment indicates
the unset section with
a continuously lit up
green button.
2. OPERATING THE JABLOTRON 100 SYSTEM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jablotron 100 and is the answer not in the manual?

jablotron 100 Specifications

General IconGeneral
Control PanelJA-101K
Events MemoryUp to 1000 events
CertificationsEN 50131 Grade 2
System TypeHybrid wireless/wired security system
CommunicationGSM, LAN
ZonesUp to 120
UsersUp to 50 users
OutputsUp to 32
Backup Battery12V 7Ah (up to 24 hours)
Mobile AppMyJABLOTRON
Number of areasUp to 15
Power Supply230V AC
Wireless RangeUp to 300 meters (open area)
CompatibilityJablotron 100 series components