21
SMS message
Sending an SMS can switch on/off a particular PG. Authorization is/isn’t demanded based on the system
configuration.
Example: CODE_CONFIGURED TEXT (“_” character = space)
MyJABLOTRON website
By clicking on ON/OFF in the Automation (PG) tab.
My JABLOTRON smartphone app
By tapping on ON/OFF in the Automation (PG) tab.
3.1 BLOCKING USERS
Any user can be temporarily blocked (e.g. when a user loses a card/tag or his access code is revealed).
When user’s access is blocked their ID code or card/tag will no longer be accepted by the system.
The users will also not receive any text message alerts or voice reports to their phone.
Only the system administrator or service technician can block a user. One method of taking away access
rights is by choosing Settings / Users / User / Bypass and selecting “Yes” on the LCD keypad. Another option
is to locally or remotely block a user through the J-Link software (Windows XP and higher) by clicking on the user
in the Settings / Users / User blocking column.
A blocked (disabled) user will be marked with a red circle until the blocking is cancelled.
3.2 BLOCKING DETECTORS
A detector can be temporarily blocked in a similar way a user can be disabled. A detector is blocked when
its activation is temporarily not desirable (for example a motion detector in a room with a pet or disable a siren
sounding). The system still performs diagnostics of tamper contacts and sends service events however the alarm
function is deactivated.
Only the system administrator or service technician can block a detector. It can be achieved by choosing
Settings / Devices / Bypass and selecting Yes on the LCD keypad. Another option is to use the J-Link software
by clicking on the detector in the Settings / Diagnostics / Disabled column. A blocked detector is marked with
a yellow circle until it is turned back on using the same procedure. A device can be also blocked from
MyJABLOTRON smartphone app.
3.3 DISABLING TIMERS
To temporarily disable automated scheduled events in the system, a timer can be disabled.
Disabling a scheduled event (e.g. unsetting the system from night guarding at a predetermined time) will prevent
execution of that event (e.g. while on vacation).
A timer can be disabled locally or remotely through the J-Link software by clicking on the section
in the Settings / Calendar / Blocked column. A disabled timer is marked with a red circle until it is turned back
on using the same procedure.
2. OPERATING THE JABLOTRON 100 SYSTEM