16
To set the entire premises in which partial setting is enabled, hold down the button to set the control panel for
2 seconds or press it twice. After the button is pressed once it shows continuous yellow light, after it is pressed
a second time it shows continuous red light.
If the system is partially set already – the function button shows a continuous yellow light – the entire system
can be fully set by authorization and pressing the yellow button for a longer time. Once the button is pressed,
the system will be fully set and the button turns red.
Partial setting can be configured in a way that authorization is not required.
In order to unset the control panel when it is partially set, press the yellow button. The control panel will unset
and the button turns green.
2.2.2.4 DURESS ACCESS CONTROL
Provides unsetting of the control panel in a special mode. The system seemingly unsets, however it triggers
a silent panic alarm, which is reported to selected users (including ARC).
Unsetting under duress is executed by adding 1 to the last number in a valid code. Contact your service
technician if you want to use this feature.
Example:
Valid code: 9999 Code for unsetting under duress: 9990
2.2.2.5 TERMINATING A TRIGGERED ALARM
A triggered alarm in progress is indicated by the status indicator and the function button rapidly flashing red.
You need to authorize yourself using the keypad in order to terminate the alarm. The section remains set,
a rapidly flashing red function button indicates the alarm memory. Indication will continue flashing even after the
system has been unset.
WARNING: If the alarm memory indication was activated during your absence, always enter the building with
caution, search for the cause of the alarm in the event history and be very careful when checking the premises or
wait until the security agency arrives (provided your system is connected to an Alarm Receiving Centre).
The alarm memory indication remains on until the system is set once again. Alternatively, it can be also
cancelled from the keypad menu: Main menu – Cancel warning indication.
Indication of a triggered tamper alarm can be terminated only by a Service technician and Administrator.
Note: When using the “Default” system profile, it is possible to select a particular action by pressing a function
button first and then confirm it by authorization using the keypad.
Terminating an alarm using a remote control will also unset the corresponding section.
1. Authorize yourself using the
keypad (enter a code or hold a
tag up to the reader).
2. Press the function button
of the section in which the alarm
has been triggered.
3. Unsetting is finished and sirens
are silenced. Rapidly
alternately flashing function
buttons (green/red) and the status
indicators indicate the alarm
memory.
2. OPERATING THE JABLOTRON 100 SYSTEM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jablotron 100 and is the answer not in the manual?

jablotron 100 Specifications

General IconGeneral
Control PanelJA-101K
Events MemoryUp to 1000 events
CertificationsEN 50131 Grade 2
System TypeHybrid wireless/wired security system
CommunicationGSM, LAN
ZonesUp to 120
UsersUp to 50 users
OutputsUp to 32
Backup Battery12V 7Ah (up to 24 hours)
Mobile AppMyJABLOTRON
Number of areasUp to 15
Power Supply230V AC
Wireless RangeUp to 300 meters (open area)
CompatibilityJablotron 100 series components

Related product manuals