15
2.2.2.2 ALARM UNSETTING
Note: If the “Unset section by authorization only during entrance delay” parameter is enabled, then mere autho-
rization will unset a section where the entrance delayed has been triggered. This option should be used with
caution when using multiple sections.
Consult the installation with a service technician in order to program the desired behaviour of the system.
2.2.2.3 PARTIAL ALARM SETTING
WARNING: This is an additional function of the alarm system.
The system can also be configured to be partially set which allows guarding only by certain detectors
in a section.
Example: At night, it is possible to set the door and window detectors only, while selected motion detectors will
not trigger the alarm when somebody moves inside the section.
1. When you enter the building
(triggering a detector with a
“Delayed zone” reaction), the
system starts indicating an entrance
delay with a continuous tone, the
system indicator and a function
button, both flashing red, of the
section in which the delayed
entrance has been triggered.
2. Authorize yourself using the
keypad – the system indicator will
start flashing green.
3. Press the function buttons of
the sections you want to unset.
4. The command is executed.
The function buttons and the
system indicator turn green
to indicate unset sections.
1. Authorize yourself using
the keypad (enter a code or hold
an RFID card or tag up to the
reader). The system indicator
button will start flashing green.
2. Press the function button of
the selected section.
3. The command is executed
and the function button turns
permanently yellow to indicate
a partially set section.
2. OPERATING THE JABLOTRON 100 SYSTEM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the jablotron 100 and is the answer not in the manual?

jablotron 100 Specifications

General IconGeneral
Control PanelJA-101K
Events MemoryUp to 1000 events
CertificationsEN 50131 Grade 2
System TypeHybrid wireless/wired security system
CommunicationGSM, LAN
ZonesUp to 120
UsersUp to 50 users
OutputsUp to 32
Backup Battery12V 7Ah (up to 24 hours)
Mobile AppMyJABLOTRON
Number of areasUp to 15
Power Supply230V AC
Wireless RangeUp to 300 meters (open area)
CompatibilityJablotron 100 series components