07610-004-33-05-E
13
SPECIFICATIONS
OPERATING PARAMETERS
Always refer to the machine data plate for specic electrical and water requirements.
The material provided on this page is for reference only and may change without notice.
i
HOT-WATER SANITIZING
Water Temperatures (°F):
RackStar
44
RackStar
66
RackStar
44S
RackStar
66S
RackStar
44ER
RackStar
66ER
Pre-wash Temperature N/A 110-140 N/A 110-140 N/A 110-140
Minimum Wash Temperature 160 160 160 160 160 160
Incoming Rinse Temperature 180 180 180 180 180 180
Minimum Incoming Water Temperature
12 kW Booster (40º Rise) 140 140 N/A N/A N/A N/A
18 kW Booster (70º Rise) 110 110 N/A N/A N/A N/A
27 kW Booster (ER Only) N/A N/A N/A N/A 110 110
No Booster 180 180
180
(from Steam
Booster)
180
(from Steam
Booster)
N/A N/A
Minimum Incoming Cold Water
Temperature (ER Units Only)
N/A N/A N/A N/A 55 55
CHEMICAL SANITIZING
Water Temperatures (°F):
RackStar
44
RackStar
66
RackStar
44S
RackStar
66S
RackStar
44ER
RackStar
66ER
Pre-wash Temperature N/A 110-140 N/A N/A N/A N/A
Minimum Wash Temperature 120 120 N/A N/A N/A N/A
Incoming Rinse Temperature 120 120 N/A N/A N/A N/A
Minimum Incoming Water
Temperature
110 110 N/A N/A N/A N/A
Other Water Requirements:
RackStar
44
RackStar
66
RackStar
44S
RackStar
66S
RackStar
44ER
RackStar
66ER
Water Flow Pressure (PSI) 15 15 15 15 15 15
Flow Rate Minimum (GPM) 1.3 1.3 1.3 1.3 1.3 1.3
Water Line Size (NPT) 1/2" 1/2" 1/2" 1/2" 1/2" 1/2"
Drain Line Size (NPT) 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2"
Steam Requirements:
RackStar
44
RackStar
66
RackStar
44S
RackStar
66S
RackStar
44ER
RackStar
66ER
Steam Line for Wash Tank (NPT) N/A N/A 3/4" 3/4" N/A N/A
Steam Flow Pressure (PSI) N/A N/A 10-30 10-30 N/A N/A
Consumption @ 15 PSI (lbs/hr) N/A N/A 60 60 N/A N/A