07610-004-33-05-E
35
To access Setup Mode, the machine should be on and preferably not in operation
(accessing this mode during operation will interrupt the process).
1. Press and hold the Up-arrow and Down-arrow Buttons until “Setup” starts
ashing (2 - 3 seconds).
2. The display will then change to “Version” and show the rmware versions of the
I/O module and UI board.
3. Use the Up-arrow Button to cycle through the categories (will be ashing).
Language • Wash Offset
Temperature Scale • Rinse Offset
Wash Temperature • Boost Offset
Boost Temperature • Spare Offset
4. Press the Select Button to choose the category you want to change.
Regardless of the category, Steps 5–7 remain the same.
5. Use the Up-arrow Button to change the options (will be ashing). Numerical
options are shown in the top window.
6. Press the Select Button to accept the changes.
7. Press the Delime Button to exit.
SETUP MODE
SETUP
LANGUAGE
LANGUAGE
ENGLISH
PROGRAMMING
TROUBLESHOOTING
Up-arrow Button
Up-arrow Button

Table of Contents