Page 15
Spa (Dual Equipment)
Turning on the spa activates the filter pump. The SPA mode must be on to display the spa temperature and/or to heat
the spa.
To use Spa (Dual Equipment)
Highlight SPA PUMP and press SELECT. Use the SELECT button to turn the spa on or off.
Two Speed Operation (*Not Available for Export Models*)
NOTE This equipment may not be part of your system. Please check with your installer.
Optional TWO SPEED RELAY required.
Two Speed Manual Operation
For Pool and Spa Combination Units
If your control is a POOL and SPA combination with a 2-speed ltration pump, the control will operate
as follows: HIGH SPEED (Filter Pump) must be on before LOW SPEED. Filter Pump button, as well
as the Spa button, turns it to HIGH SPEED. LOW SPEED (AUX 2) button toggles back and forth from
LOW to HIGH.
For Pool or Spa Only Units
To use HIGH/LOW Speeds, Filter Pump turns on HIGH SPEED, AUX 2 turns on LOW SPEED.
Whatever mode last used is the off button. To toggle, press whichever speed is not on.
For Dual Equipment Units
AquaLink RS 2/6 operates the same as the Pool/Spa Only units; i.e., Filter Pump turns on HIGH
SPEED and AUX 2 turns on LOW SPEED. The mode last used is the off button. To toggle, press
whichever speed is not on. 2-speed works only on spa lter pump.
Two Speed Programming for All Units
When programming HIGH and LOW Speeds to operate together, think of HIGH SPEED (Filter Pump)
as total duration of ltration time, then set Low Speed (AUX 2) to operate within that duration. For
example, if you want High Speed on for 2 hours and Low Speed for 10 hours, program the Filter Pump
(High Speed) from 8 AM to 8 PM and Low Speed from 10 AM to 8 PM.
NOTE It is not necessary to program both HIGH and LOW Speeds, even with a Combo Control System. If only LOW SPEED is
programmed, HIGH SPEED will turn on at the LOW SPEED on time to prime the pump. After 3 minutes the system will
switch to LOW SPEED for the remainder of its programmed time.
OFFFILTER PUMP OFF
SPA PUMP
POOL HEAT
SPA HEAT
AUX 1
AUX 2
AUX 3
AUX 4
AUX 5
AUX 6
AUXB1
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
MORE
FILTER PUMP
SPA PUMP
POOL HEAT
SPA HEAT
AUX 1
AUX 2
AUX 3
AUX 4
AUX 5
AUX 6
AUXB1
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
MORE

Other manuals for Jandy AquaLink RS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy AquaLink RS and is the answer not in the manual?

Jandy AquaLink RS Specifications

General IconGeneral
BrandJandy
ModelAquaLink RS
CategoryControl Panel
LanguageEnglish

Related product manuals