Page 29
ENGLISH
Installation and Operation Manual
|
Jandy
®
Legacy™ Model LRZE Pool/Spa Heater by Zodiac
®
the thermostat setting (desired temperature) to be
greater than the water temperature. The igniter
lights the burner when the thermostat calls for
heat.
9. Set the time clock, if one is installed.
Complete shutdown instructions are as follows:
1. Set both temperature controls to their lowest
setting.
2. Turn off the control. Make sure the display shows
that the heater is off.
3. Turn off all electrical power to the heater at the
junction box.
4. Open the heater door and turn the gas valve knob
clockwise to off.
5. Shut off the external gas supply valve to the
heater.
Thewaterpressureswitchshouldbeadjustedto
turntheheateroffwhenthepumpisoff.Settingthe
switchtocloseattoolowofaowcandamagethe
appliance.Adjusttheswitchtoturntheheateroff,
noton.
Lemanocontactdepressiond’eaudoitêtreréglé
defaçonàcequel’appareilcessedefonctionner
silapompes’arrête.Silemanocontactestréglé
poursefermerlorsqueledébitd’eauesttropfaible,
l’appareilrisquedes’endommager.Réglezlemano-
contactpourqu’ilarrêtel’appareil,etnonpourqu’il
lemetteenmarche.
The pressure switch is preset at the factory for
activation at 2 psi (14 kPa). Do not adjust the pressure
switch if the heater is installed more than 15 feet (4.57
m) below the pool surface. Consult your local Jandy
representative for recommendations.
On some installations, the piping from the heater
to the pool is very short. The back pressure could be
too low to trigger the pressure switch. If this happens,
it may be necessary to install a directional tting or
elbows where the return line enters the pool. This will
increase back pressure enough for the heater to operate
properly.
Donotattempttolighttheheaterwiththedooroff.
Doingsomaycauseseverebodilyinjury.
Netentezpasd’allumerl’appareilsansquela
portesoitenplace.Vouspourriezêtrevictimede
blessurescorporellesgraves.
Before starting your heater, be sure that all of the
functions and limits of the Legacy controller have been
set according to the previous sections of this manual.
Once the control is set to your preferences, follow the
instructions outlined below. Read and follow all safety
instructions rst. A more detailed set of lighting and
shutdown instructions are listed on the label located on
the inside of the heater door and in Figure 21.
Lighting instructions are as follows:
1. Turn off all electrical power to the heater at the
main junction box.
2. Remove the heater door and turn the heater gas
valve to off.
3. Wait 5 minutes before trying to start the heater.
4. Turn the gas valve control knob counterclock-
wise to ON. See Figure 20.
5. Replace the heater door.
6. Turn on electrical power to the heater.
7. Turn on the lter pump.
Inordertoavoidpossibleseriousinjury,donot
exceedtherecommendedsafemaximumtempera-
tureasspeciedinSection1.2.
8. Set the heater control to the "SPA" mode. If the
temperature of the water exceeds the thermostat
setting it is necessary to increase the thermostat
setting to exceed the water temperature. Adjust