9. ConnecttheDCcordtothepowercenter.FeedtheDCcordthroughthesamestrainreliefttingasthe
ow/temp/salinitysensor. Plug the DC cord into the two spade connectors of the wiring harness located
in the low voltage raceway of the control/power center, see Figure 2a, 2b, and 2c. This wiring harness
establishes the connection between the cell and the power interface PCB.
10. Tightenstrainreliefttingscrewsfortheow/temp/salinitysensor and the DC cord. Do not pull
Flow/Temp/Salinity Sensor cable or DC Cord too tight. Allow a little slack for the cable inside of
power center enclosure.
CAUTION
Donotovertightenthestrainrelieftting.Overtighteningcancausedamagetotheow/temp/salinity
sensor cable.
11. Prior to reattaching front cover, check the wiring. Be sure the ow/temp/salinitysensor is plugged in.
The DC cord should be plugged in. Also, check the AC wiring.
12. PlugoneendoftheribboncableintothebackoftheuserinterfaceandtheotherendintotheJ1
connector on the power interface PCB (see Figures 2a, 2b, 2c, and 10).
WARNING
Toavoidpropertydamage,seriousinjuryordeath,donotoperatetheelectrolyticcellwithoutwater
circulation.AbuildupofammablegasescanresultinFIREorEXPLOSION.
3.7.2 Replacement of Existing 3-Port Cell (Universal or 2” PVC Unions)
1. Be sure pool pump is turned off.
2. Unplug DC cable from existing cell. Disconnect the DC cord from the wiring harness as shown in
Figure2a,2b,and2c.Loosenthestrainreliefttingthatalsocontainsthecableforow/temp/salinity
sensor. Pull the DC cord out through the strain relief.
CAUTION
DonotallowtheDCCordtopulltootightlyonow/temp/salinitysensorcableasitisbeingpulled
throughthestrainrelief.Thismaydamagetheow/temp/salinitysensorcableanditsconnectiontothe
printed circuit board.
3. Removeow/temp/salinitysensorfromcellbyunscrewingcouplingnutonsensorport.Thesensor
should pull straight out after nut is removed.
4. Removeold3-portcellbodybyunscrewingcouplingnutsonowports.Thecellbodywillbefreeto
pull out after nuts are clear of the threads.
5. Replaceexistinguniono-ringswithnewo-ringsprovidedwithcellkit.
6. Install new cell and tighten coupling nuts.
7. Installtheow/temp/salinitysensorintotheavailablesensorport(SeeFigure11).
8. Plug the new DC cord provided with the cell kit, in either direction, into the cell stud terminals
protruding from the cell top. Make sure that the plug is fully inserted and bottomed out on the housing.
CAUTION
Toavoidriskofdamagetotheequipmentandpossibleinjury,itisimportanttomakesuretheDCcable
connector is fully seated on the cell stud terminals.

Table of Contents

Other manuals for Jandy PureLink

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy PureLink and is the answer not in the manual?

Jandy PureLink Specifications

General IconGeneral
BrandJandy
ModelPureLink
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals