3.7 Installing the Electrolytic Cell and Flow/Temp/Salinity Sensor
Please choose one of the following instructions to either install or replace the cell and sensor assembly.
3.7.1 New Installation
3.7.2 Replacement of Existing 3-Port Cell
3.7.3 Replacement of 2-Port (square) Cell and Sensor Tee with 3-Port Cell
NOTE: Maximum operating Pressure is 345 kPa or 50 PSI - Minimum Flow Rate is 30 GPM (114 LPM).
WARNING
ATTENTIONINSTALLER:Iftheow/temp/salinitysensorisnotinstalledproperly,itmayallowthe
electrolyticcelltooperatewithoutwaterow.Thiswouldcauseabuildupofammablegasesresultingin
FIRE or EXPLOSION.
• MountasshowninFigure11.Thiswillresultinthemostreliableoperation.
• Theow/temp/salinitysensormustbemounted:
(1) In one of the available ports in the electrolytic cell
- or -
(2)Inthesamelinepriortothecellwithnovalvesordivertersbetweentheow/temp/salinity
sensor and cell.
• Anytimetheow/temp/salinitysensorisconnectedordisconnectedandreconnected,theACpower
to the unit must be turned off and back on (Cycle Power). If power is not cycled, unreliable operation
oftheow/temp/salinitysensorwillresult.
3.7.1 New Installation
1. Be sure pool pump is turned off.
2. Itisrecommendedthattheow/temp/salinitysensorandelectrolyticcellbeinstalledinthepoolreturn
lineafterthelterandheater.Thecellcanbeinstalledineitherahorizontaloraverticalposition.See
Figure 3.
3. Positiontheow/temp/salinitysensorandcellintherecommendedposition(seeFigures1,3,4and5).
4. Locate a suitable section of pipe, approximately 17 inches (432 mm) long or follow the recommended
plumbingdiagramsasshowninFigures4and5.Theow/temp/salinitysensor cable and cell DC cord
must be able to reach from the power center to this section of pipe.
5. Cutouta13
7
/
8
(352mm)sectionofthe2(50mm)pipetoinserttheCell.SeeFigure12.Glueon
unions and install cell.
6. Install the ow/temp/salinitysensor into the 3-Port cell. See Figure 11.
7. Install the strain relief provided with the electrolytic cell kit into the low voltage knock out. Feed
the connector end of the ow/temp/salinitysensorcablethroughtheDCcordstrainrelieftting.Be
certain the connector is clean and dry, then plug the cable into the connector on the power center
printed circuit board as shown in Figures 2a, 2b, and 2c. (Do not pull Flow/Temp/Salinity Sensor
cable too tight, allow a little slack).
8. Plug the DC cord into the cell stud terminals protruding from the cell top. The DC cord can be plugged
into the cell in either direction.
CAUTION
Toavoidriskofdamagetotheequipmentandpossibleinjury,itisimportanttomakesuretheDCcable
connector is fully seated on the cell stud terminals.

Table of Contents

Other manuals for Jandy PureLink

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jandy PureLink and is the answer not in the manual?

Jandy PureLink Specifications

General IconGeneral
BrandJandy
ModelPureLink
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals