118
Be sure the fuel tank has fuel in it prior to operating the fuel pump. Make sure the fuel is
not contaminated with debris.
1. Attach the grounding clip to the item or vehicle being fueled.
2. Outside the vehicle at the Fueling Station, pull the master/emergency disconnect switch
to the “ON” position.
3. Inside the vehicle, press the fuel pump momentary switch time. Pushing this switch
turns on the pump, and a timer which will automatically turn o the fuel pump after 15
minutes have elapsed (pressing this switch times turns o the timer and the pump).
4. Outside the vehicle, insert the fuel nozzle into the receiving tank and squeeze the nozzle
handle to dispense the fuel.
Make sure the fuel nozzle grounding clip is always attached to the com-
ponent or vehicle receiving fuel.
Make sure the pump is properly maintained as instructed by the fuel
pump manufacturer’s operator manual. Make any necessary repairs prior
to operation.
When the fueling station is not in use, the fuel pump switch and
the master/emergency disconnect switch should both be turned “OFF”.
Boththe inside fuel pump switch and the master/ emergency
disconnect switch must be turned on to dispense fuel.
Do not continue adding fuel after the fuel pump’s automatic shut
off stops dispensing fuel. Do not pump fuel tank completely dry as contami-
nates from the bottom of the tank may enter the pump.
IF THE FUEL STATION EQUIPMENT DOES NOT FUNCTION AS IN-
TENDED, DISCONTINUE USE AND HAVE THE FUEL STATION SER-
VICED BEFORE RESUMING USE.